PM-29 Process Meter Code No. : PM-29

PM-29 Download pdf

3-3/4 Digits, Digital Multimeter Cum DC mV / Voltage / Frequency / Resistance / mA Calibrator and also provides output for all types of Thermocouples, Code No. : PM-29

3-3/4 Digits, Digital Multimeter Cum DC mV / Voltage / Frequency / Resistance / mA Calibrator and also provides output for all types of Thermocouples, Code No. : PM-29

Technical Specifications

  • Digital Process Calibrator cum Multimeter 
  • It measures and sources various parameters.
  • Display: 3-3/4 Digits 3999 Counts Backlit LCD
  • Confirms to IEC 61010
  • Data Hold
  • In Measure Mode:
  • DC Voltage: 0 – 4 / 40 / 400V Accuracy of ±0.2%
  • DC milli Volt: 0 – 40m / 400mV Accuracy of ±0.2% 
  • AC Voltage :  0 – 400m / 4 / 40 / 400V Accuracy of ±0.2%
  • DC Current : 0 – 40m / 400mA Accuracy: ±0.2%
  • AC Current: 0 – 40m / 400mA Accuracy: ±0.5%
  • Resistance: 0 – 400 / 4k / 40k / 400k / 4M / 40M.Ohms  Accuracy:  ±0.2%
  • Frequency: 0 – 50 / 500 / 5k / 50k / 100kHz Accuracy: ±0.1%
  • Temperature through PT-100 Sensor: -200°C to 700°C Accuracy:  ±0.5%
  • Temperature through Cu-50 Sensor: -50°C to 150°C Accuracy: ±0.5%
  • Temperature through R type Sensor: -40°C to 1760°C Accuracy: ±0.5%
  • Temperature through S type Sensor: -20°C to 1760°C Accuracy: ±0.5%
  • Temperature through B type Sensor: 400°C to 1800°C Accuracy: ±0.5%
  • Temperature through E type Sensor: -200°C to 500°C Accuracy: ±0.5%
  • Temperature through K type Sensor: -200°C to 950°C Accuracy: ±0.5%
  • Temperature through J type Sensor: -200°C to 700°C Accuracy: ±0.5%
  • Temperature through T type Sensor: -200°C to 400°C Accuracy: ±0.5%
  • Temperature through N type Sensor: -200°C to 1000°C Accuracy: ±0.5%
  • Diode Test and Continuity Test Facility
  • In the source mode:
  • Resistance: 0 – 400 Ohms Accuracy: ±0.5%
  • DC milli Volt: -10 – 100mV Accuracy: ±0.5% 
  • DC Voltage: -0.5 to 5.5V Accuracy: ±0.2%
  • Frequency: 0 – 100 / 1k / 10kHz Accuracy: ±0.2%
  • XMT in the range: 0 to -20mA Accuracy: ±0.2%
  • DC Milli Ampere: 0 to 22mA Accuracy: ±0.2% 
  • Temperature output for Pt-100 Sensor: -200°C to 850°C Accuracy: ±0.5%
  • Temperature output for Cu-50 Sensor: -50°C to 150°C Accuracy: ±0.5%
  • Temperature output for R type Sensor: -40°C to 1760°C Accuracy: ±0.5%
  • Temperature output for S type Sensor: -20°C to 1760°C Accuracy: ±0.5%
  • Temperature output for B type Sensor: -40°C to 1800°C Accuracy: ±0.5%
  • Temperature output for E type Sensor: -200°C to 1000°C Accuracy: ±0.5%
  • Temperature output for K type Sensor: -200°C to 1370°C Accuracy: ±0.5%
  • Temperature output for J type Sensor: -200°C to 700°C Accuracy: ±0.5%
  • Temperature output for T type Sensor: -200°C to 400°C Accuracy: ±0.5%
  • Temperature output for N type Sensor: -200°C to 1300°C Accuracy: ±0.5%

Reviews